A solid insulated ring main unit (solid insulated RMU) is a fully sealed, metal-clad medium voltage switchgear built for ring network power distribution. Unlike conventional SF6 gas-insulated RMU, all live conductive parts are encapsulated in high-performance epoxy resin solid insulation, paired with vacuum interrupters for arc extinction. It eliminates SF6 greenhouse gas, delivers stable insulation performance, and reduces maintenance workload, making it a preferred eco-friendly MV switchgear for modern power grids worldwide.
As a professional solid insulated RMU manufacturer from China, Xinhong Electrical designs and produces solid insulated ring main units complying with IEC standards. Our solid insulated RMU features modular construction, compact footprint, strong environmental adaptability and optional smart grid integration. This article covers core specifications, key benefits and typical use cases to help engineers, EPC contractors and utility buyers select suitable solid insulated RMU for distribution projects.
Solid insulated RMU is a compact modular switchgear for 12kV medium voltage three-phase AC distribution systems. The high-voltage live circuit, vacuum interrupter and busbar are fully cast inside epoxy resin. Functional units connect via shielded solid insulated busbars. The whole primary circuit is isolated from humidity, dust, pollution and condensation, achieving fully insulated and fully sealed operation.
The equipment integrates load break switch, circuit breaker, fuse combination unit, PT unit and metering unit. It supports ring network power supply and terminal power supply, and can be equipped with protection relays and communication modules to realize distribution automation for smart grid projects.
| Item | Parameter |
|---|---|
| Rated Voltage | 12kV |
| Rated Frequency | 50Hz / 60Hz |
| Rated Current | 630A, 1250A |
| Rated Short-time Withstand Current | 20kA, 25kA, 31.5kA (4s) |
| Power Frequency Withstand Voltage | 42kV phase to earth / phase to phase |
| Lightning Impulse Withstand Voltage | 75kV |
| Partial Discharge | ≤20pC |
| Enclosure Protection Class | IP4X |
| Insulation Medium | Epoxy resin solid insulation, SF6-free |
| Arc Extinguishing | Vacuum interrupter |
| Compliance Standard | IEC 62271-200, ISO, CE, CB |
Note: Xinhong Electrical supports customized solid insulated RMU configuration according to project requirements, including feeder quantity, protection scheme and smart monitoring functions.
Solid insulated RMU is widely adopted for indoor and outdoor medium voltage distribution projects, especially where space is limited or SF6 restriction applies.
City cable ring networks, small secondary substations, underground power rooms, tunnel power distribution and urban grid renovation projects. Its compact size fits narrow underground spaces and dense urban areas.
Distributed solar PV stations, wind farms and battery energy storage systems (BESS). Solid insulated RMU provides reliable grid connection, fault isolation and power switching for new energy plants.
High-rise buildings, residential communities, shopping malls, hospitals, airports, rail transit and metro power supply systems. Continuous power supply capability ensures critical loads stay online during grid faults.
Industrial parks, manufacturing plants, chemical and mining facilities. The robust anti-pollution and anti-corrosion performance adapts to harsh industrial environments.
Perfect matching equipment for prefabricated box substations. Solid insulated RMU works together with distribution transformers and low-voltage panels as a complete power distribution package.
For projects with carbon reduction requirements or sites with poor ventilation, Xinhong Electrical solid insulated RMU becomes a more sustainable long-term option.
Xinhong Electrical is a China-based manufacturer of medium voltage power equipment with rich experience in MV switchgear production. Our solid insulated ring main units are factory tested and certified by ISO, CE and CB.
We provide:
If you need solid insulated RMU quotation or technical proposal for your power distribution project, contact our engineering team for detailed support.
Solid insulated ring main unit is a sustainable, safe and reliable medium voltage switchgear solution for modern ring distribution networks. With SF6-free solid insulation, vacuum interruption, compact structure and wide environmental tolerance, solid insulated RMU has become a mainstream choice for urban grid renovation, new energy, rail transit and industrial power projects.
Xinhong Electrical from China supplies high-quality solid insulated RMU with full certifications and custom service. Talk to our team to find the optimal solid insulated ring main unit solution for your next power project.